Specifications

Contact resistance

100 mΩ max.

Insulation resistance

100 MΩ min.

Voltage proof

An AC voltage of 250 V and an induced current of 1 mA shall be applied between terminals, and between terminals and frame, for one minute.

Terminal strength

A static force of 300 g shall be applied in one direction to the tip of the terminal for 1 minute.

Operating force

Soldering test

The tips of the terminals shall be dipped 2 mm into a solder bath at a temperature of 235±5℃ for 3 seconds.

Soldering resistant test

The manual soldering temperature shall be 350±5℃ for a soldering time of 3±0.5 seconds; however, excessive pressure shall not be applied to the terminal.

Reflow soldering heat test

Moisture resistant test

40±2℃ 90-95% RH for 96 hours. Test after keeping in normal condition for 30 minutes.

Cold resistant test

At -40±3℃ for 96 hours. Test after keeping under normal conditions for 30 minutes.

Heat resistant test

At 80±2℃ for 96 hours. Test after keeping under normal conditions for 30 minutes.

Wave soldering test

Under Sealing Pack

Under sealing pack condition, stored temperature doesn't exceed 30℃ and relative humidity is 75% RH. In the environment of no sunshine direct and no corrosive gas, the stored time ought to be three months but within six months at most.

Without Sealing Pack

Without sealing pack condition, stored temperature doesn't exceed 30℃ and relative humidity is 75% RH. In the environment of no sunshine direct and no corrosive gas, the stored time shouldn't exceed 168H. Don't excessive overlap or overstocking when keeping these goods, in case of damage.

Request Pricing, Custom Specs, or Samples for This Series

Submit your required pin configurations, target quantities, or CAD requests. Our application engineers will confirm lead times and pricing within 24 hours.